Ceph RBD benchmarking¶
How to characterize Ceph RBD performance from a Kubernetes pod with fio,
what targets to expect on this hardware, and the setup mistakes that make
naive runs read low without telling you why.
When to run¶
- After hardware changes that could move the floor (NIC upgrade, new OSD hardware, replication factor change, network re-cabling).
- Before/after Ceph version bumps if perf is in question.
- To validate a perf regression complaint is real, not a one-off.
- To establish a baseline before tuning (so you can prove tuning helped).
Do not rely on a mixed randrw from a single client at a single block
size to characterize the cluster — see Common pitfalls.
Methodology¶
Run separate fio jobs for each metric. Mixing read+write or sizes in one run gives you a number that doesn't compare to anything.
The four axes that matter:
| Axis | What it measures | Test |
|---|---|---|
| Read IOPS | Small random read ceiling | 4K randread, high QD |
| Write IOPS | Small random write ceiling (replication-bound) | 4K randwrite, high QD |
| Read BW | Sequential read ceiling (network-bound) | 1M seqread, moderate QD |
| Write BW | Sequential write ceiling (network + replication) | 1M seqwrite, moderate QD |
Read IOPS is the easy ceiling — primary OSD responds, done. Write IOPS is the interesting one: every write goes to all replicas, so write IOPS at 3x replication costs ~3x the cluster work of a read. That's where you'll see network bottlenecks first.
Cluster expectations¶
NVMe-only Ceph cluster, replication=3, healthy 10 GbE+ inter-OSD network, single client to a single RBD image:
| Test | Reasonable range |
|---|---|
| 4K randread, QD=64 numjobs=4 | 30k–80k IOPS |
| 4K randwrite, QD=64 numjobs=4 | 10k–25k IOPS |
| 1M seqread, QD=32 | ~80–95% of network line rate |
| 1M seqwrite, QD=32 | ~30–45% of network line rate (3x replication) |
| Avg read latency | 1–3 ms |
| Avg replicated write latency | 3–8 ms |
A single client at single QD can never hit cluster max — these are "reasonable single-client" numbers, not cluster aggregate. To exercise the cluster ceiling, run the same fio Job from 3–4 pods on different nodes in parallel and sum the results.
If single-client numbers come back 5–10× low with 5–10× high latency, the bottleneck is almost always the network, not the OSDs. Verify the path:
# From the test pod's node, check the link to a remote OSD
ip -s link show $iface
ethtool $iface | grep Speed
On fairy specifically: cn02, cn03, and the DGX Sparks are on a transient 1 GbE uplink while r02-tor01 cabling is being migrated. Until that migration completes, benchmarks from cn01 against OSDs on those nodes will be capped at ~80–110 MiB/s of effective throughput regardless of the cluster's actual capability.
Test pod setup¶
Diagnostic namespace + a single PVC + Job. Adjust nodeSelector to pin to
the node you're characterizing.
---
apiVersion: v1
kind: Namespace
metadata:
name: ceph-bench
---
apiVersion: v1
kind: PersistentVolumeClaim
metadata:
name: bench
namespace: ceph-bench
spec:
storageClassName: ceph-block
volumeMode: Block
accessModes: ["ReadWriteOnce"]
resources:
requests:
storage: 50Gi
---
apiVersion: batch/v1
kind: Job
metadata:
name: ceph-bench
namespace: ceph-bench
spec:
backoffLimit: 0
ttlSecondsAfterFinished: 86400
template:
spec:
restartPolicy: Never
nodeSelector:
kubernetes.io/hostname: fairy-r02-cn01 # change me
tolerations:
- operator: Exists
containers:
- name: fio
image: alpine:3.20
command: ["/bin/sh", "-euc"]
args:
- |
set -eu
apk add --no-cache fio >/dev/null
# Pre-fill the device so reads don't hit zero-deduped pages.
fio --name=prefill --filename=/dev/block --rw=write \
--bs=1M --iodepth=8 --numjobs=2 --size=20G \
--ioengine=libaio --direct=1 --group_reporting
run() {
echo "=== $1 ==="
fio --name="$1" --filename=/dev/block \
--ioengine=libaio --direct=1 --time_based \
--runtime=120 --group_reporting \
--output-format=normal "${@:2}"
echo
}
# Read IOPS ceiling
run randread-4k --rw=randread --bs=4k --iodepth=64 --numjobs=4
# Write IOPS ceiling
run randwrite-4k --rw=randwrite --bs=4k --iodepth=64 --numjobs=4
# Read BW ceiling
run seqread-1m --rw=read --bs=1M --iodepth=32 --numjobs=1
# Write BW ceiling
run seqwrite-1m --rw=write --bs=1M --iodepth=32 --numjobs=1
echo "== done $(date -u +%FT%TZ) =="
volumeDevices:
- { name: bench-pvc, devicePath: /dev/block }
volumes:
- name: bench-pvc
persistentVolumeClaim:
claimName: bench
Use volumeMode: Block and --direct=1 so you measure RBD, not the host
page cache. The prefill pass writes real data so reads hit allocated extents
instead of getting served zero-fill from object thin-provisioning.
Cluster-aggregate variant¶
To exercise the whole cluster, duplicate the Job pinned to a different node per copy (cn01, cn02, cn03, dgx01…) and run them simultaneously. Sum the read/write IOPS and BW from each pod's output. That's your cluster ceiling for the workload mix.
Reading the results¶
The output sections that matter:
- IOPS / BW — the headline numbers.
- clat p50 — median latency. Should be tight on NVMe (1–3 ms read).
- clat p99 / p99.99 — tail latency. A wide gap from p50 means contention somewhere (network queue, OSD WAL flush, deep PG queue).
slat (submission latency) is rarely interesting — that's kernel overhead
before the IO is in flight.
Common pitfalls¶
- Mixed
randrwin one fio job: reads and writes contend on the same queue and saturate the wrong resource first. Always split. - No
--direct=1: the host page cache absorbs the IO and you measure RAM, not Ceph. - No prefill on a
volumeMode: BlockPVC: reads against unwritten thin-provisioned blocks return zero-fill instantly with no OSD round trip. Numbers look unrealistically high. - Single QD, single job: leaves the cluster idle. Use enough concurrency (numjobs × iodepth ≥ 64) to actually exercise the PGs.
- Network-bottlenecked node: a single link at 1 GbE caps everything, but the symptom looks like "slow OSDs" or "high latency." Always check the link speed of the client and the OSDs being read from.
- Comparing across runs without holding everything else constant: Ceph perf moves with deep scrub state, OSD compaction, even time of day. Run baseline and "after" within a short window for a fair compare.
Cleanup¶
The PVC is deleted with the namespace; the underlying RBD image is reclaimed